KEY FEATURES
5-Year-Old Child
- 6 hours of battery life
- Rechargeable
- Wireless control
- 7’’ or 10” tablet provided as control panel
- Articulated joints in the neck, shoulder, hip, and knee for easy mobility
- Anatomical features such as oral cavity, tongue, teeth, glottis, epiglottis, trachea, esophagus, right and left lungs, and stomach
- A steel spring system designed to provide realistic chest compression during CPR while preventing collapse during application
GENERAL APPLICATIONS
- The simulator can be voice-activated through the control panel for realistic anamnesis practice.
- Bilateral IV puncture, injection, transfusion, and blood drawing procedures through the basilic and cephalic veins in the anterior forearm and the dorsal surface of the hand.
- Bilateral IM injection into the deltoid muscle of the upper arm.
- Intraosseous infusion (IO) procedure on the left leg.
AIRWAY MANAGEMENT
- Oral and nasal endotracheal intubation can be performed.
- LMA, LTA, and Combitube applications can be simulated.
- During endotracheal intubation, the control panel monitors the correct placement of the endotracheal tube within the trachea while detecting accidental insertion into the right bronchus or esophagus. *
* This feature is available exclusively for the ST-151+ model.
| ST/151 | ST/151+ | |
| RECHARGEABLE | ✓ | ✓ |
| WIRELESS CONTROL | ✓
7” TABLET |
✓
10” TABLET |
| CPR | ✓ | ✓
INSTANT FEEDBACK |
| ANAMNESIS SIMULATION | ✓ | ✓ |
| ECG & DEFIBRILLATION | ✓ | ✓ |
| PULSE SYNCHRONIZED WITH ECG | RIGHT FEMORAL | RIGHT FEMORAL & CAROTID |
| INTUBATION | ✓ | ✓
ELECTRONIC DETECTION OF TUBE POSITION |
| IV- IM INTERVENTION ON BOTH ARMS | ✓ | ✓ |
| IO INTERVENTION ON THE LEFT LEG | ✓ | ✓ |
| FEEDBACK REPORTS FOR CPR AND INTUBATION PRACTICES | ✓ | |
| HDMI KIT | ✓ |
CPR AND CARDIOLOGY PRACTICES
- The femoral pulse is synchronized with the selected ECG rhythm.
- The carotid pulse is synchronized with the selected ECG rhythm. *
- Mouth-to-mouth, mouth-to-nose, or balloon-valve-mask ventilation can be performed. Realistic chest elevation can be observed.
- Realistic bilateral and unilateral chest rise can be observed.
- It provides a system feature that enables monitoring of CPR applications and intubation procedures via the control panel, supports tracking of correct practices, and allows effective management of the training process.*
- Features a control panel capable of analyzing insufficient, sufficient, and excessive ventilation during artificial respiration applications, detecting air directed into the stomach, and monitoring correct/incorrect procedures via the tablet.*
- Features a control panel that monitors correct hand positioning during chest compressions, provides feedback for insufficient, sufficient, and excessive force applications, and records correct/incorrect procedures.*
- Generate a comprehensive report providing detailed feedback on CPR and intubation practices.*
- Forty-three distinct ECG rhythms, each with adjustable heart rates controlled through the control panel, can be displayed utilizing four ECG leads.
- Non-invasive blood pressure (BP) measurement: the systolic (SBP) and diastolic (DBP) blood pressure values can be adjusted through the control panel. The Korotkoff sounds heard during measurement are synchronized with the selected ECG rhythm rate.
- Real defibrillation, cardioversion, and AED applications can be safely performed on the model using an actual defibrillator, AED, and bedside monitor. The model is equipped with secure defibrillation (shock) points, ensuring the safety of the procedures.
- A virtual bedside monitor kit with the following features is provided along with the simulator:*
– The virtual bedside monitor kit can be used with all devices with HDMI connector (TV, projection, monitor, etc.).
– All commands of the virtual bedside monitor kit are controlled wirelessly via tablet.
– Virtual bedside monitor shows ECG, SpO2, AwRR, etCO2, Temp., NIBP, Glucose, CVP values. These values can be adjusted on the tablet.
– Virtual bedside monitor kit provides heartbeat sounds synchronized with ECG.
– Alarms are available. Alarm intervals can be adjusted.
– The virtual bedside monitor has 43 different ECG rhythms. The heart rate of these rhythms can be adjusted.
* This feature is available exclusively for the ST-151+ model.
Not: Models and brands of clothing and accessories may vary.